Docs
Download Spikemark
  • Creative Conners Docs
  • Technical Support
    • Tech Tips
      • Revolver V1 Position Issues
      • Setting Up a New Comptuer for Spikemark
  • Spikemark 6
    • Navigating Spikemark
      • Show Modes
      • Workspaces
        • Jog Workspace
        • Cues Workspace
        • Preset Workspace
        • Customize Your Workspace
      • Selection and Input
      • Tags
      • Filters
      • Search
      • Keyboard Shortcuts
    • Cues
      • Cue Structure
      • Cue Creation
        • Add Movements
        • Add Triggers
        • Add Actions
      • Editing Cue Properties
      • Cue Deletion
    • Movements
      • Motor Movements
      • Locked Group Movements
      • Unlocked Group Movements
      • FX Movements
      • OSC Movements
        • Custom OSC Command Library
      • UDP Movements
      • Modbus Movements
    • Triggers
      • Playback Go Trigger
      • Delay Trigger
      • Completion Trigger
      • Position Trigger
      • FX Input Trigger
      • Stacking Triggers
    • Actions
      • Motor Property Action
      • Motor Method Action
      • Playback Property Action
    • Running Cues
      • Playbacks
        • Playback Editing
        • Playback Control Speed
        • Playback Stacking
      • Cue Controls
      • Console
      • Consolette
      • Restore Cue
    • Spikes
      • Simple Spikes
      • Dynamic Spikes
        • Incremental Spikes
        • Nearest Forward Multiple Spikes
        • Nearest Reverse Multiple Spikes
        • Nearest Multiple Spikes
      • Locked Group Spikes
    • Presets
      • Presets Overview
      • Creating, Editing, and Deleting Presets
      • Running Presets
    • User Authentication and Authorization
      • Overview
      • Users
      • Roles
      • Permissions
    • Show Control
      • Open Sound Control (OSC)
        • Send OSC Messages
        • OSC Position Output
        • OSC Input Trigger
          • OSC Input Messages
          • Cue Messages
          • Playback Messages
          • Sequence Step Messages
          • Motor Movement Messages
          • Motor Messages
        • Troubleshooting OSC
          • OSC Response Window
          • Medialon Manager Configuration
      • UDP
        • Send UDP Messages
        • UDP Position Output
      • Watchout Position Output
      • PosiStageNet (PSN)
  • Spikemark 5
    • How to Open Spikemark
    • Spikemark Installation
      • User Authorization
      • Windows Settings
    • Quick Start Tutorial
      • Step 1: Adding Motors
        • 1.1 Simulator Mode
        • 1.2 Add Motors from the Machine Library
        • 1.3 Rename Motors
        • 1.4 Add A Group
      • Step 2: Saving
      • Step 3: Jogging
        • 3.1 Single Axis Jogging
        • 3.2 Jogging Multiple Machines (Multi-Jog)
        • 3.3 Move To Position
      • Step 4: Writing Your First Cues
        • 4.1 Cues Workspace
        • 4.2 Add A Movement
        • 4.3 Duplicate A Cue
        • 4.4 Delete A Movement From A Cue
        • 4.5 Edit Movement - Changing Position, Speed, and Time
        • 4.6 Copy to Group
        • 4.7 Cue Total Time
        • 4.8 Load and Run your Cue
        • 4.9 Spikes
        • 4.10 Cue Links
        • 4.11 Restore Cue
        • 4.12 Delete A Cue
      • Step 5: Going Live
        • 5.1 Set Your IP Address
        • 5.2 Test Manual Movement
        • 5.3 Resetting Position
        • 5.4 Program Your Show
      • Sharpen Your Programming Skills
    • Steps to a Successful Load-In
    • Show Modes
    • Locking Changes
    • Workspaces
      • Customize Your Workspace
    • Selection and Input
    • IP Address and Network Connection
      • Setting Computer IP Address
      • Setting Stagehand IP Address
      • Setting Showstopper Consolette IP Address
      • Setting Pendant IP Address
      • Setting Showstopper IP Address
      • Setting Showstopper Node ID
      • Connecting To A Stagehand
      • Connecting To A Showstopper Consolette
      • Connecting To A Pendant
    • Adding Motors or Machines
      • Adding Motors or Machines From The Machine Library
      • Adding Custom Motors or Machines To Spikemark
      • Importing Motors or Machines
      • Exporting Motors or Machines
    • Stage Model Viewer
      • Changing Your Viewer
      • Adjusting the Stage Size
      • Changing the Type of Scenery
      • Adjusting Model Dimensions
      • Adjusting Model Rotation
      • Adjusting Location On Stage
      • Making Models
        • Modeling A Winch
        • Modeling A Lift
        • Modeling A Hoist
        • Modeling A Vertical Curtain
        • Modeling A Split Curtain
        • Modeling A Turntable or Periaktos
    • Tags
    • Editing Direction Labels
    • Filters
    • Search
    • Position
      • Reset Position
      • Units
      • Position Scale
        • Position Scale Wizard
        • Manually Calculate Position Scale
      • Limits
        • Setting Hard Limits
        • Setting Soft Limits
      • Target Tolerance
      • Strict Timing Mode
      • Position Fault and Max Position Error
      • Motor Tuning Overview
        • Motor Tuning - The Practical Approach
    • Load Cell
      • Load Cell Readout
      • Load Cell Configuration
      • Load Cells and Groups
    • Speed
    • Spikes
      • Adding A Spike
      • Removing A Spike
      • Spike Input Fields
      • Simple Spike
      • Incremental Spike
      • Nearest Forward Multiple Spike
      • Nearest Reverse Multiple Spike
      • Nearest Multiple Spike
    • Editing Cues
      • Adding and Deleting Cues
      • Adding and Deleting Movements
      • Edit Movement
      • Edit Cue Options
    • Cue Controls
    • Cue Status
    • Cue Links
      • Completion Link
      • Time Link
      • Position Link
      • Input Link
      • Deleting A Cue Link
    • Presets
    • Motor Groups
    • Showstopper Node Editor
    • Show Control
      • Open Sound Control (OSC)
        • OSC Position Output
        • OSC Messenger
          • Expanding The Command Library
        • OSC Response Window
        • OSC Input Trigger
          • Input Messages
          • Cue Commands
          • Motor Commands
          • My OSC Input Trigger Isn't Working, Is there another way?
      • UDP
        • UDP Position Output
        • UDP Messenger
      • Watchout Position Output
      • Modbus Effect
      • PosiStageNet (PSN)
    • Drive Communication
      • Drive Information
      • Configuring The Drive
      • Analyzing Movements
      • Drive Communication: Compatibility
      • Drive Communication: Setting VFD Parameters
      • RS-485 Upgrade
        • Upgrading an A800
        • Upgrading an A700
        • Drive Communication Troubleshooting
      • VFD Fault Codes
    • Motor Status Icons
    • Keyboard Shortcuts
    • Advanced Cue Techniques
  • Showstopper
    • Showstopper 4 Base
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Spikemark Console
      • Making-The-Connections
      • Using-the-Console
      • Console-Firmware
      • Troubleshooting
      • Specifications
    • Spikemark Pendant V2
      • Getting Started
      • Setup
      • Operation
      • Troubleshooting
      • Specifications
      • Drawings
    • Showstopper 4 E-Stop Hub
      • Getting Started
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper 4 Accessory Hub
      • Getting Started
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper Remote E-Stop
      • Installation
      • Making The Connections
      • Operation
      • Troubleshooting
      • Specifications
    • Control Connection
      • Installation
      • Making The connections
      • Operation
      • Troubleshooting
      • Specifications
    • Drive Connection
      • Installation
      • Making The connections
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper E-Stop Patch Panel
    • Showstopper Accessory Patch Panel
    • 🦺Safety Interlock
      • Safety Interlock Classic
      • Safety Interlock Pro
      • Safety Interlock Pro 4
      • 4-Axis Safety Interlock
    • Legacy
      • Showstopper 3 Base
      • Showstopper 3 Remote
      • Showstopper 3 E-Stop Patch Panel
      • Stage Manager
        • Getting Started
        • Installation
        • Making the Connections
        • Operation
        • Troubleshooting
        • Specifications
      • Showstopper 4 Consolette
        • Features
        • Making the Connections
          • Accessory Cable Connection
          • Ethernet Connection
          • Multiple Consolettes
        • On-Board Settings
        • Operation & Spikemark Integration
        • Connecting the Consolette to Spikemark
        • Jogging Motors
        • Running Cues
        • Emergency Stop
        • Updating Consolette Firmware
        • Troubleshooting
        • Physical Specifications
        • Drawings
  • Stagehand
    • Stagehand Firmware
      • Manually Updating a Stagehand Unipolar V6 Card via SD Card
      • Manually Updating a Stagehand Unipolar V6 Card via USB
    • Stagehand Parameters
      • Stagehand Pro 2 Parameters
      • Stagehand Pro 3/Pro 4 Parameters
      • Stagehand Pro 3e Parameters
      • Stagehand Pro 5 Parameters
      • Stagehand Apprentice 2 Parameters
      • Stagehand Apprentice
      • Stagehand AC - AKA: The Classic
      • Classic+ Parameters
      • Pro+ Parameters
      • Setting the C3 Value
      • Setting the C4 Value
      • All Clear/Parameter Clear
      • How to Use the Mitsubishi VFD Keypad
      • USB Parameter Sets
      • Parameter Library in Spikemark
    • Stagehand Apprentice
      • Getting Started
      • Installing the Stagehand
      • Making the Connections
      • Hooking up a motorized effect
      • Using the Stagehand
      • Troubleshooting
      • Technical Support
      • Specifications
    • Stagehand Apprentice DC
    • Stagehand Apprentice 2
      • Stagehand Apprentice 2: Features
      • Stagehand Apprentice 2: Installation
      • Stagehand Apprentice 2: Making The Connections
        • Stagehand Apprentice 2: Power Input
        • Stagehand Apprentice 2: Motor and Brake Output
        • Stagehand Apprentice 2: Sensor Input
        • Stagehand Apprentice 2: Interlock Inputs
        • Stagehand Apprentice 2: Ethernet Input
        • Stagehand Apprentice 2: Showstopper Emergency Stop Input
      • Stagehand Apprentice 2: Operation
      • Stagehand Apprentice 2: Troubleshooting
      • Stagehand Apprentice 2 Specifications
      • Stagehand Apprentice 2: Drawings
    • Stagehand FX
      • Getting Started
      • Making the Connections
      • Connecting an Effect
      • Operation
      • Troubleshooting
      • Specifications
    • Stagehand Hydraulic
      • Getting Started
      • Features
      • Installation
      • Operation
      • Troubleshooting
      • Technical Support
      • Specifications
      • Drawings
    • Stagehand Pro 3
    • Stagehand Pro 3E
    • Stagehand Pro 4
      • Stagehand Pro 4: Unpacking
      • Stagehand Pro 4: Installation
      • Stagehand Pro 4: Making The Connections
        • Stagehand Pro 4: Power Input
        • Stagehand Pro 4: Motor and Brake Output
        • Stagehand Pro 4: Sensor Input
        • Stagehand Pro 4: Interlock Inputs
        • Stagehand Pro 4: Ethernet Input
        • Stagehand Pro 4: Showstopper Emergency Stop Input
      • Stagehand Pro 4: Operation
        • Stagehand Pro 4: Powering Up
        • Stagehand 4: Machine Configuration
        • Stagehand Pro 4: Manual Operation (Jogging)
        • Stagehand Pro 4: Brake Test
        • Stagehand Pro 4: Connecting to Spikemark
        • Stagehand Pro 4: Status Displays
      • Stagehand Pro 4: Troubleshooting
        • Stagehand Pro 4: Recovering From Faults
        • Stagehand Pro 4: Monitoring Behavior
      • Stagehand Pro 4: Specifications
      • Stagehand Pro 4: Drawings
    • Stagehand Pro 5
      • Stagehand Pro 5: Features
      • Stagehand Pro 5: Installation
      • Stagehand Pro 5: Making The Connections
        • Stagehand Pro 5: Power Input
        • Stagehand Pro 5: Motor and Brake Output
        • Stagehand Pro 5: Sensor Input
        • Stagehand Pro 5: Interlock Inputs
        • Stagehand Pro 5: Ethernet Input
        • Stagehand Pro 5: Showstopper Emergency Stop Input
      • Stagehand Pro 5: Operation
      • Stagehand Pro 5: Troubleshooting
      • Stagehand Pro 5 Specifications
      • Stagehand Pro 5: Drawings
      • Stagehand Pro 5: Replace Control Card
    • Deck Chief 2
      • Getting Started
      • Features
      • Making the Connections
      • Using the Deck Chief
      • Troubleshooting
      • Specifications
    • Stagehand Classic+
    • Stagehand Pro+
    • Legacy Manuals
      • Deck Chief
        • Getting Started
        • Installation
        • Making the Connections
        • Using the Deck Chief
        • Troubleshooting
        • Specifications
        • Deck Chief Legacy Connections
      • Stagehand Mini^2
      • Stagehand Pro AC (Pro 2)
      • Stagehand AC
      • Stagehand Mini
      • Stagehand DC & DC Max
    • X-Groove Override
  • Machinery
    • Smart Chain Hoist
      • Getting Started
      • Installation
      • Making the Connections
      • Under The Hood
      • Troubleshooting
      • Specifications
    • Floorpocket
      • GettingStarted
      • Installation
      • Making the Connections
      • Prepping the Machine for Operation
      • VFD Settings
      • Troubleshooting
      • Specifications
    • Floorpocket v2
      • Get Started
        • Unpack
        • Installation Tools
      • Assembly
        • Base
        • Column Extension
        • Limit Cables
        • Roller Chain
      • Get Moving
        • Power Up
        • Platform
        • Stay Safe
        • Write Cues
      • Maintain the Machine
      • Troubleshooting
      • Floorpocket v2: Specifications
    • Pivot
      • Getting Started
      • Installation
      • Troubleshooting
      • Specifications
    • Pushstick
      • Getting Started
      • Installation
      • Making the Connections
      • Rigging the Pushstick
        • Rigging a Pushstick v2
      • Setting the Limits
      • Troubleshooting
      • Specifications
    • Pushstick Mini
      • Getting Started
      • Installation
      • Making the Connections
      • Rigging the Pushstick Mini
      • Troubleshooting
      • Technical Support
      • Specifications
    • Revolver
      • Installation
      • Making the Connections
      • Making It Move
        • Friction Wheel Tension Guide
      • Position Scaling
        • Encoder Finessing
      • Troubleshooting
      • Specifications
        • Drawing
      • Multi-Motor Configuration
      • Revolver v1 Manual
    • Rotator
      • Getting Started
      • Installation
      • Making the Connections
      • Troubleshooting
      • Technical Support
      • Specifications
    • Spotline
      • Getting Started
      • Installation
      • Rigging the Spotline
      • Operation
      • Troubleshooting
      • Specifications
    • Spotline V2
      • Spotline V2: Setup Process
      • Spotline V2: Installation
      • Spotline V2: Rigging the Spotline
      • Spotline V2: Operation
      • Spotline V2: Troubleshooting
      • Spotline V2 Accessories
      • Spotline V2: Maintenance
      • Spotline V2: Specifications
    • Spotline Mini v2
    • Spotline Practical
      • Practical v2
        • Getting Started
        • Installation
        • Rigging the Machine
        • Setting the Limits
        • Troubleshooting
        • Specifications
      • Practical v1
        • Getting Started
        • Installation
        • Operation
        • Troubleshooting
        • Specifications
    • Turntable Template
      • Overview
      • Bill Of Materials
      • Fabrication
      • Turntable Assembly and Installation
      • Turntable Assembly Guide
      • Tech Support
      • 20' Turntable Specs
      • Turtable Research Notes for Nerds
    • Retired
      • Curtain Call
      • Trickline
        • TricklineProductManualv1.0
        • Getting Started
        • Installation
        • Making the Connections
        • Troubleshooting
        • Specifications
      • Spotline Mini
        • Getting Started
        • Installation
        • Making the Connections
        • Rigging the Spotline Mini
        • Troubleshooting
        • Specifications
      • Pushstick Manual
    • Stromag Limits
  • Broadweigh Load Cells
Powered by GitBook
On this page
  • 1 - Getting Started
  • 1.1 - Safety
  • 1.2 - Curtain Call Overview
  • 1.3 - Installing the Curtain Call
  • 2 - Rigging the Curtain Call
  • 3 – Troubleshooting
  • Technical Support
  • 4 – Specifications
  • 4.1 Physical Specifications
  • 4.2 Specifications

Was this helpful?

  1. Machinery
  2. Retired

Curtain Call

PreviousRetiredNextTrickline

Last updated 10 months ago

Was this helpful?

1 - Getting Started

Congratulations on your purchase of the Curtain Call traveller track winch from Creative Conners, Inc. Curtain Call is a winch designed to meet the demands of scenic automation.

This manual will direct you through:

  1. Unpacking

  2. Installing & testing

  3. Operation procedures

If you need help along the way contact us either on our website (), via email (), or by phone (401.289.2942)

1.1 - Safety

The Curtain Call is a fantastic machine for moving scenery and curtains on many different types of traveller tracks. Curtain Call is a friction drive winch, and grips the operating line to pull scenery or curtains along the traveller track. It offers great flexibility but also requires serious planning and safety. The Curtain Call is not intended for any use other than lateral movement on a traveller track.

Curtain Call is rated for 180 pounds of line pull and a maximum travel speed of 36 in/sec at 60Hz.

1.2 - Curtain Call Overview

Curtain Call can be used with a variety of traveler tracks and durable enough for the rigors of day-to-day life in the theater industry. The major components of the Curtain Call are shown below:

- Gearmotor

- Electromechanical Brake

- Speed Reducer

- Incremental Encoder

- 3-Groove Drive Pulley

- 3-Groove Tension Pulley

- Adjustable Idler Sheave

Figure 1.1

1.3 - Installing the Curtain Call

1.3.1 - Mounting the Curtain Call

Curtain Call can be easily mounted to either a batten or truss. Place the Curtain Call at the end of your batten/truss and attach with the provided Mega Clamp®. When positioning the Curtain Call, take a little time to ensure that it is hanging plumb, if the machine isn’t plumb it could lead to improper tension in the system. After Curtain Call is secured to the batten/truss adjust the idler sheave to the height of the tracks return/turnaround pulley.

Figure 1.2

1.3.2 - Connecting the Curtain Call to a Stagehand

Prior to rigging the Curtain Call lets make sure the machine working properly. To power up the Curtain Call you will need a Stagehand 1HP-2HP controllers (refer to your Stagehand manual for installation instructions). With the Stagehand installed, make the following connections between the Curtain Call and Stagehand:

  1. Connect the encoder to the encoder socket.

  2. Connect the brake to the brake socket.

  3. Connect the motor to the motor socket.

  4. Connect either the forward limit or a limit jumper to the forward limit socket.

Note: A limit jumper is a ML1 plug that has a wire connected between the two pins on the plug. This will simulate a normally closed limit switch, thus allowing travel in the forward direction.

  1. Connect either the reverse limit or a limit jumper to the reverse limit socket.

  2. Using a network cable (RJ45 Cat5), connect the Ethernet socket to an Ethernet hub.

  3. Using a Showstopper cable (5-pin XLR) connect the Showstopper to the E-Stop inlet on the Stagehand AC.

1.3.3 - Testing the Curtain Call

It is important to confirm your Curtain Call is properly connected to the Stagehand, to do so you should test these conditions:

  1. E-Stop – Release the E-Stop button on Showstopper. You should hear a “click” from inside the Stagehand, this is the E-Stop contactor closing. The LCD display should show that the E-Stop is released by switching the status display to:

Figure 1.3

“Not Connected” indicates that the Stagehand is not communicating with a computer running Spikemark.

  1. Brake release – Press the fwd jog button. You should hear a distinct “click” from your brake. This is the sound of the brake releasing. Release the fwd job button. You should hear a click of the brake engaging.

  2. Motor Motion – Press the fwd jog button and slowly turn the knob clockwise. The motor should begin moving. Turn the knob counterclockwise to slow the motor to a stop, then release the jog button. Repeat with the rev jog button.

  3. Limit Switches – Manually activate (or unplug) first the forward limit, then the reverse limit. The LCD display on the Stagehand should indicate when a limit is detected.

Figure 1.4

2 - Rigging the Curtain Call

Once you have confirmed the Curtain Call is properly functioning without a load attached the machine can now be rigged. Because the Curtain Call uses friction to pull the scenery or curtain, proper tension and the type of hauling line have a big impact on accuracy. For best results we recommend to using ¼” OD Coated Wire Rope, McMaster-Carr #8912T539.

Figure 2.1 (With Side Plate Removed)

  1. Cut the length of required wire rope, often twice your traveller length plus 10’-0” (i.e. 40’-0” traveller length, (4X40’-0”+10’-0”=90’-0”))

  2. Adjust the tensioner so the pulleys are as low as they will go on the winch.

  3. Rig the return line first by attaching one end of your wire rope to your Master Carrier and attach it to the side furthest from the Curtain Call.

  4. Run the wire rope through the track turnaround pulley and head back to the Curtain Call

  5. Run the wire rope through the idler pulley and down to the 3-Groove Drive Pulley

  6. Run the cable up to the tension and back down to the drive pulley, do this twice.

  7. Once the 3-Groove drive pulley is full take the cable back up to the remaining tension pulley, run the line in front of the pulley and up to the remaining idler pulley.

  8. Now secure the cable to the Master Carrier.

  9. Begin to take tension out the system by the bottom nut on the tensioner assembly, use a 1-1/8” wrench, do this slowly.

  10. Begin to drive the Curtain Call in a slow speed while you take tension, this allows tension to be taken equally throughout the system. Repeat until the tension in the system meets a satisfactory level. After tension is completed tighten the top and bottom nut in the tensioner assembly to ensure the tensioner wont come loose over time.

  11. Once system is rigged, place the limit switches in their respective spots on the pipe and install the Limit Actuator on the Master Carrier.

  12. Install the Limit Switch Actuator to the Master Carrier. The Master carrier will have holes allowing you to install the Actuator with the supplied ¼”-20 bolt. See Figure 2.2 for clarification.

  13. Test to ensure the Limit Switch Actuator is making contact with the Limit Switch and registering on your Stagehand.

Figure 2.2

Your Curtain Call is now ready to move your scenery!

3 – Troubleshooting

Though the combination of the Curtain Call, Spikemark, Stagehand, and Showstopper strive to make automation easy and plug and play, sometimes things don’t operate properly. This part of the guide will point out some culprits to keep an eye out for throughout your troubleshooting process.

Motor is jerky.

Check tension of wire rope. The wire rope should be taught throughout the system. Any slack in the system could cause backlash. Make sure the rope isn’t too taught.

Adjust tuning parameters in Spikemark.

When running a cue, proper accuracy isn’t being achieved.

Check tension of wire rope, the wire rope could be slipping on the drive pulley causing unstable positioning.

Check the termination in master carrier to ensure the haul line isn’t slipping through the terminations.

When running a cue, the motor speeds fast in the wrong direction and then turns off.

The polarity of the motor is reversed. Open up the motor plug and switchany two of the three power wires (always leave the green wire connected to the ground pin).

Technical Support

Though we try our best to produce reliable products and clear instructions, there may come a time when you need personal support.

Phone Support

You can call our technical support at 401-289-2942 Monday-Saturday from 8am – 6pm EST. Phone support is free for 90 days, after that a rate of $30/hr. may apply to support calls.

Web Support

Email

4 – Specifications

4.1 Physical Specifications

4.2 Specifications

Input voltage

1hp AC 230V 60Hz 3-phase

Max input current

1hp AC 3.2 amps

Max line pull

1hp 180 lbs.

Max line speed 36 in/sec

Suggested Haul Line ¼” OD Coated Wire Rope, McMaster #8912T539

There is an active user support forum on our website.

If you have a technical question you can email technical support .

www.creativeconners.com
support@creativeconners.com
http://www.creativeconners.com/phpBB3/index.php
support@creativeconners.com
LCD not connected
LCD forward limit