Troubleshooting
We aim to make any product as plug and play as possible, though sometimes challenges crop up right out of the box or years down the road. See below for solutions to common operational challenges.
Motion
Issue | Checkpoint |
Motion is not smooth | Confirm cable is wrapped flat on the drum. |
Confirm practical effect is travelling perpendicular to drum, not catching on idler pulley | |
Confirm cable and practical effect path is clear of obstructions. | |
Check PID tuning in Spikemark:
| |
Motor is spinning, drum is not moving | Confirm drive chain is connected and intact and under tension. |
Rigging
Issue | Checkpoint |
Cable is rubbing on idler pulley or keeper. | Level machine. |
Machine is experiencing faults at repeating locations | Verify that your practical effect weighs at least 5lbs and the cable is feeding cleanly onto the idler pulley Verify Max Speed is set correctly in Spikemark |
Onboard Stagehand Display
Stagehand Display | Checkpoint |
E STOP + IP Address | The E-stop cable is unplugged or the E-stop is engaged. |
DISCONNECTED + IP Address | Machine is on and ready to connect to Spikemark. |
CONNECTED + IP Address | Machine is on and connected to Spikemark. |
SET IP | Confirm the IP Address is correct, use the scroll wheel to highlight OK and click. |
SET SUBNET | Confirm display shows 255.255.255.0, use the scroll wheel to highlight OK and click. |
DRIVE FAULT | The Servo Drive is in a fault state, reset from Spikemark or by removing the main power at the breaker for 30 seconds. |
BRAKE FAULT | you have a problem with the wiring of your brake. If you experience a brake fault, your machine is likely in need of repair and you should give us a call at 401-289-2942 x2, or drop us a line at support@creativeconners.com |
FWD LIMIT + IP Address | The Forward limit is engaged. Manually jog off the limit and adjust the set screw of the rotary limit. |
REV LIMIT + IP Address | The Reverse limit is engaged. Manually jog off the limit and adjust the set screw of the rotary limit. |
ULT Limit + IP Address | The Forward Ultimate or Reverse Ultimate limit is engaged or a slack line has been detected. First, verify that the slackline rod arm is captured behind the lifting cable, and reset if in front of the cable. Then, manually jog off the limit and adjust the set screw of the rotary limit. |
Blank Display | Check main power and local breaker. |
Connection/Power
Issue | Checkpoint |
Stagehand display is blank | Confirm machine power is connected and the local breaker is ON. |
Able to manually jog the machine from the Stagehand but unable to connect through Spikemark | Confirm IP Address is set correctly on the Stagehand, in your computer’s network settings, as well as in Spikemark. |
Confirm Ethernet cable is connected. | |
Confirm network switch is connected and powered on. | |
LX Power not transmitting | Check breaker on side of Stagehand, continuity from input receptacle to cable PowerCON connector |
LX Data not transmitting | Check continuity from input receptacle to cable EtherCON connector |
TECHNICAL SUPPORT
If you get stuck, we’re here to help. The best way to get in touch with a tech expert is via email - even during normal business hours - because most days we are spread around the shop and may not be near the phone. There’s someone in the office from 8:30a-5pm EST Monday - Friday and will return an email or phone call quickly. After hours (honestly when most tech support issues arise) we have a crack team monitoring email and voicemail who will respond quickly to help get you moving.
Online: www.creativeconners.com
Email: support@creativeconners.com
Phone: 401-289-2942 x2