> For the complete documentation index, see [llms.txt](https://docs.creativeconners.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.creativeconners.com/docs/stagehand/stagehand-pro-5/stagehand-pro-5-specifications.md).

# Stagehand Pro 5 Specifications

### Physical Specification <a href="#h.yz18i1kwtonp" id="h.yz18i1kwtonp"></a>

<table data-header-hidden><thead><tr><th width="376"></th><th></th></tr></thead><tbody><tr><td>Description</td><td>Value</td></tr><tr><td>Dimensions</td><td>19”(W) x 20”(D) x 10.5”(H)</td></tr><tr><td>Rack Unit Height</td><td>6U</td></tr><tr><td>Weight</td><td>52lbs</td></tr><tr><td>Shipping Dimensions</td><td>24”x24”x18”</td></tr><tr><td>Shipping Weight</td><td>62lbs</td></tr></tbody></table>

### Electrical Specifications <a href="#h.i4n01987irkh" id="h.i4n01987irkh"></a>

| Description                                       | 5HP E800 208VAC E800                                            | 5HP 380VAC-460VAC E800                                            | 7.5HP 380VAC-460VAC E800                                          |
| ------------------------------------------------- | --------------------------------------------------------------- | ----------------------------------------------------------------- | ----------------------------------------------------------------- |
| UL Listed                                         | Conforms with UL508a Standard for Industrial Control Panels     | Conforms with UL508a Standard for Industrial Control Panels       | Conforms with UL508a Standard for Industrial Control Panels       |
| Input Voltage                                     | 3 Phase 200-240VAC 50/60hz                                      | 3 Phase 380-480VAC 50/60hz                                        | 3 Phase 380-480VAC 50/60hz                                        |
| Input Connector                                   | L15-30 or L21-30                                                | L22-20                                                            | L22-30                                                            |
| Max Current Draw                                  | 30A                                                             | 20A                                                               | 30A                                                               |
| Motor Output Voltage                              | 230VAC                                                          | 460VAC                                                            | 460VAC                                                            |
| Min Motor Output                                  | 2Hp                                                             | 2HP                                                               | 5.5HP                                                             |
| Max Motor Output                                  | 5HP                                                             | 5HP                                                               | 7.5HP                                                             |
| Min Motor Speed                                   | 0.5Hz                                                           | 0.5Hz                                                             | 0.5Hz                                                             |
| Max Motor Speed                                   | 120Hz                                                           | 120Hz                                                             | 120Hz                                                             |
| Motor and Load Brake Output                       | 1 Phase 200-240VAC 50/60Hz                                      | 1 Phase 380-480VAC 50/60Hz                                        | 1 Phase 380-480VAC 50/60Hz                                        |
| Max Brake(Motor and Load Combined) Output Current | 6A                                                              | 6A                                                                | 6A                                                                |
| Emergency Stop Input Voltage                      | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Emergency Stop Input Current                      | 85mA                                                            | 85mA                                                              | 85mA                                                              |
| Limit Switch Voltage                              | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Limit Switch Current                              | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Limit Switch Signal Type                          | dry contact / potential free                                    | dry contact / potential free                                      | dry contact / potential free                                      |
| Cross-Groove Switch Voltage                       | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Cross-Groove Switch Current                       | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Cross-Groove Signal Type                          | dry contact / potential free                                    | dry contact / potential free                                      | dry contact / potential free                                      |
| Load Cell Voltage                                 | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Load Cell Signal                                  | 4-20mA Analog Signal                                            | 4-20mA Analog Signal                                              | 4-20mA Analog Signal                                              |
| Speed Encoder Voltage                             | 5VDC                                                            | 5VDC                                                              | 5VDC                                                              |
| Speed Encoder Type                                | Incremental, Quadrature, Line Driven                            | Incremental, Quadrature, Line Driven                              | Incremental, Quadrature, Line Driven                              |
| Position Encoder Voltage                          | 5VDC                                                            | 5VDC                                                              | 5VDC                                                              |
| Position Encoder Type                             | Incremental, Quadrature, Line Driven                            | Incremental, Quadrature, Line Driven                              | Incremental, Quadrature, Line Driven                              |
| Max Encoder(Speed and Position Combined) Current  | 1A                                                              | 1A                                                                | 1A                                                                |
| Interlock Switch Voltage                          | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Interlock Switch Current                          | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Interlock Signal Type                             | Dry contact / potential free                                    | Dry contact / potential free                                      | dry contact / potential free                                      |
| Network Input                                     | 10Base-T Ethernet                                               | 10Base-T Ethernet                                                 |                                                                   |
| Commissioning Port                                | USB-B                                                           | USB-B                                                             | USB-B                                                             |
| 24VDC Control Circuit Fuse                        | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p> | <p>2.5A Medium-Acting 5mm x 20mm</p><p>Littelfuse 023402.5MXP</p> | <p>2.5A Medium-Acting 5mm x 20mm</p><p>Littelfuse 023402.5MXP</p> |
| 5.5VDC Control Circuit Fuse                       | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p> | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>   | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>   |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.creativeconners.com/docs/stagehand/stagehand-pro-5/stagehand-pro-5-specifications.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
