# Stagehand Pro 5 Specifications

### Physical Specification <a href="#h.yz18i1kwtonp" id="h.yz18i1kwtonp"></a>

<table data-header-hidden><thead><tr><th width="376"></th><th></th></tr></thead><tbody><tr><td>Description</td><td>Value</td></tr><tr><td>Dimensions</td><td>19”(W) x 20”(D) x 10.5”(H)</td></tr><tr><td>Rack Unit Height</td><td>6U</td></tr><tr><td>Weight</td><td>52lbs</td></tr><tr><td>Shipping Dimensions</td><td>24”x24”x18”</td></tr><tr><td>Shipping Weight</td><td>62lbs</td></tr></tbody></table>

### Electrical Specifications <a href="#h.i4n01987irkh" id="h.i4n01987irkh"></a>

| Description                                       | 5HP E800 208VAC E800                                            | 5HP 380VAC-460VAC E800                                            | 7.5HP 380VAC-460VAC E800                                          |
| ------------------------------------------------- | --------------------------------------------------------------- | ----------------------------------------------------------------- | ----------------------------------------------------------------- |
| UL Listed                                         | Conforms with UL508a Standard for Industrial Control Panels     | Conforms with UL508a Standard for Industrial Control Panels       | Conforms with UL508a Standard for Industrial Control Panels       |
| Input Voltage                                     | 3 Phase 200-240VAC 50/60hz                                      | 3 Phase 380-480VAC 50/60hz                                        | 3 Phase 380-480VAC 50/60hz                                        |
| Input Connector                                   | L15-30 or L21-30                                                | L22-20                                                            | L22-30                                                            |
| Max Current Draw                                  | 30A                                                             | 20A                                                               | 30A                                                               |
| Motor Output Voltage                              | 230VAC                                                          | 460VAC                                                            | 460VAC                                                            |
| Min Motor Output                                  | 2Hp                                                             | 2HP                                                               | 5.5HP                                                             |
| Max Motor Output                                  | 5HP                                                             | 5HP                                                               | 7.5HP                                                             |
| Min Motor Speed                                   | 0.5Hz                                                           | 0.5Hz                                                             | 0.5Hz                                                             |
| Max Motor Speed                                   | 120Hz                                                           | 120Hz                                                             | 120Hz                                                             |
| Motor and Load Brake Output                       | 1 Phase 200-240VAC 50/60Hz                                      | 1 Phase 380-480VAC 50/60Hz                                        | 1 Phase 380-480VAC 50/60Hz                                        |
| Max Brake(Motor and Load Combined) Output Current | 6A                                                              | 6A                                                                | 6A                                                                |
| Emergency Stop Input Voltage                      | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Emergency Stop Input Current                      | 85mA                                                            | 85mA                                                              | 85mA                                                              |
| Limit Switch Voltage                              | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Limit Switch Current                              | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Limit Switch Signal Type                          | dry contact / potential free                                    | dry contact / potential free                                      | dry contact / potential free                                      |
| Cross-Groove Switch Voltage                       | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Cross-Groove Switch Current                       | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Cross-Groove Signal Type                          | dry contact / potential free                                    | dry contact / potential free                                      | dry contact / potential free                                      |
| Load Cell Voltage                                 | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Load Cell Signal                                  | 4-20mA Analog Signal                                            | 4-20mA Analog Signal                                              | 4-20mA Analog Signal                                              |
| Speed Encoder Voltage                             | 5VDC                                                            | 5VDC                                                              | 5VDC                                                              |
| Speed Encoder Type                                | Incremental, Quadrature, Line Driven                            | Incremental, Quadrature, Line Driven                              | Incremental, Quadrature, Line Driven                              |
| Position Encoder Voltage                          | 5VDC                                                            | 5VDC                                                              | 5VDC                                                              |
| Position Encoder Type                             | Incremental, Quadrature, Line Driven                            | Incremental, Quadrature, Line Driven                              | Incremental, Quadrature, Line Driven                              |
| Max Encoder(Speed and Position Combined) Current  | 1A                                                              | 1A                                                                | 1A                                                                |
| Interlock Switch Voltage                          | 24VDC                                                           | 24VDC                                                             | 24VDC                                                             |
| Interlock Switch Current                          | 10mA                                                            | 10mA                                                              | 10mA                                                              |
| Interlock Signal Type                             | Dry contact / potential free                                    | Dry contact / potential free                                      | dry contact / potential free                                      |
| Network Input                                     | 10Base-T Ethernet                                               | 10Base-T Ethernet                                                 |                                                                   |
| Commissioning Port                                | USB-B                                                           | USB-B                                                             | USB-B                                                             |
| 24VDC Control Circuit Fuse                        | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p> | <p>2.5A Medium-Acting 5mm x 20mm</p><p>Littelfuse 023402.5MXP</p> | <p>2.5A Medium-Acting 5mm x 20mm</p><p>Littelfuse 023402.5MXP</p> |
| 5.5VDC Control Circuit Fuse                       | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p> | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>   | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>   |


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.creativeconners.com/docs/stagehand/stagehand-pro-5/stagehand-pro-5-specifications.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.