Showstopper 3 E-Stop Patch Panel
Reference Manual v1.-
Last updated
Reference Manual v1.-
Last updated
Congratulations on your purchase of Showstopper 3 E-Stop Patch Panel from Creative Conners, Inc! The Showstopper 3 E-Stop Patch Panel expands the capabilities of your Showstopper 3 Emergency Stop Network. The Showstopper 3 E-Stop Panel purpose built for permanent installation allowing you to connect Stagehand Controllers to your Showstopper 3 Emergency Stop Network around your venue. The Showstopper 3 E-Stop Panel is designed with simple wire terminations and the ability to patch into your existing Showstopper 3 Emergency Stop Network with ease.
This manual will guide you through:
Unpacking
Installation
Connecting Devices
Troubleshooting
1 x Showstopper 3 E-Stop Patch Panel (3U)
If any of these components are missing, please contact us for a replacement.
Sleek and stylish or boring but informational faceplate? You decide.
Label Placeholder- Convenient outlines for labeling the Drive Connection Points around your venue.
2 Pole Screw Terminals - (10) 2P 5A Female Mini Combicon Header Phoenix Contacts for terminating pins 1-2 for +24VDC permanently installed Showstopper E-Stop cables.
E-Stop Input - 10 E-Stop inputs for connecting to the E-Stop outputs of your Showstopper 3 Base or Showstopper 3 E-Stop Hub.
The Showstopper 3 E-Stop Patch Panel is a 3U rack mountable case designed to fit in a standard 19" rack with (4) #10-32 rack-mount screws.
As with all our devices, they need to be connected to function.
Each Stagehand and smart machine requires a direct connection to a Showstopper 3 Base or Showstopper 3 E-Stop Hub. These connections are made with a Neutrik 5-pin XLR cable. There’s no tech wizardry here, any 5-pin XLR cable will work as long as the polarity is correct. The 5-pin XLR cable is not a DMX signal, but rather it was chosen as a convenient cable that is prevalent in many venues so you should always be able to find a spare cable when needed.
Below is the pin-out for the Showstopper Emergency Stop output:
All challenges faced with the Showstopper 3 E-Stop Patch Panel will only be connection issues.
Check that you are connected to an E-Stop Output of a Showstopper 3 Base or Showstopper 3 E-Stop Hub as the source.
Check that your screw terminals are wired correctly.
Check that your screw terminals have a tight connection.
Verify that the Stagehand Controller in your Showstopper 3 Emergency Stop Network is connected.
If you get stuck, we’re here to help. The best way to get in touch with a tech expert is via email - even during normal business hours - because most days we are spread around the shop and may not be near the phone. There’s someone in the office from 8:30a-5pm EST Monday - Friday and will return an email or phone call quickly. After hours, (honestly when most tech support issues arise) we have a crack team monitoring email and voicemail who will respond quickly to help get you moving.
Phone: 401-289-2942 x2
The Showstopper 3 E-Stop Patch Panel is packaged in a standard 19” x 3U rackmount case. The overall dimensions are: 17”W x 8”D x 5-1/8”H.
If you need help along the way contact us on our website (), via email (), or by phone (401-289-2942 x2). We want your automation to succeed and we are eager to help you through any head-scratching issues.
Online:
Email:
Description
Value
E-Stop Input/Output Voltage
24VDC