Stagehand Pro 2 Parameters
There are a lot of parameters - just 1 mis-set parameter can cause countless hours of troubleshooting chaos.
If you've confirmed the parameters below, aren't seeing a Brake Fault and are feeling stuck, it's time to start from scratch by resetting the VFD back to factory settings. Once you have reset the VFD you'll need to manually input the Stock Parameters.
Set parameter 77 = 2 before jumping into manually entering parameters!
Jump to the bottom of the page to find the proper values for each of our stock machines.
Stagehand Pro 2 Stock Parameters
No. | Name | Notes | Setting value |
---|---|---|---|
0 | Torque boost | Compensate for low torque in V/f mode | 4 |
1 | Maximum frequency | Max frequency output from the VFD | 120 |
2 | Minimum frequency | Min frequency output from the VFD | 0 |
3 | Base frequency | From motor nameplate | 60 |
7 | Acceleration time | Drive level - not used | 0 |
8 | Deceleration time | Drive level - not used | 0 |
9 | Electronic thermal O/L relay/Rated motor current | From motor nameplate | 17.5 |
10 | DC injection brake operation frequency | Hz level when the VFD will apply the DC injection braking | 0.5 |
11 | DC injection brake operation time | DC injection brake timing | 0.5 |
12 | DC injection brake operation voltage | Voltage applied (% of input voltage) | 4 |
13 | Starting frequency | VFD will not start below this value | 0.5 |
22 | Stall prevention operation level (torque limit level) | Torque limit (%) | 200 |
30 | Regenerative function selection | Brake resistor installed | 1 |
70 | Special regenerative brake duty | Based on braking resistor installed | 10 |
71 | Applied motor | 3 = Induction motor | 3 |
72 | PWM frequency selection | Performance & noise | 15 |
73 | Analog input selection | +/-10VDC with reversing | 14 |
77 | Parameter write selection | enabled across all states | 2 |
79 | Operation mode selection | External operation | 0 |
80 | Motor capacity | From motor nameplate | 3.7 |
81 | Number of motor poles | Nameplate motor RPM 2=3500rpm, 4=1750rpm, 6=1150rpm | 4 |
83 | Rated motor voltage | From motor nameplate | 230 |
84 | Rated motor frequency | From motor nameplate | 60 |
96 | Auto tuning setting/status | 0 | |
117 | PU communication station number | Modbus | 1 |
118 | PU communication speed | Modbus | 384 |
119 | PU communication stop bit length / data length | Modbus | 0 |
120 | PU communication parity check | Modbus | 0 |
121 | Number of PU communication retries | Modbus | 1 |
122 | PU communication check time interval | Modbus | 9999 |
125 | Terminal 2 frequency setting gain frequency | Set what 100% = in hertz (overspeed) | 60 |
152 | Zero current detection level | % of VFD rated current | 5 |
153 | Zero current detection time | seconds to detect zero current | 0.1 |
156 | Stall prevention operation selection | V/f & Magnetic flux modes only | 0 |
180 | RL terminal function selection | I/O | 9999 |
181 | RM terminal function selection | I/O | 9999 |
182 | RH terminal function selection | I/O | 50 |
183 | MRS terminal function selection | I/O | 9999 |
184 | RES terminal function selection | I/O | 9999 |
190 | RUN terminal function selection | I/O | 199 |
191 | SU terminal function selection | I/O | 9999 |
192 | IPF terminal function selection | I/O | 9999 |
193 | OL terminal function selection | I/O | 9999 |
194 | FU terminal function selection | I/O | 9999 |
195 | ABC1 terminal function selection | I/O | 99 |
252 | Override Bias | old school overspeed | 100 |
285 | Overspeed detection frequency (speed deviation excess detection frequency) | too fast | 20 |
316 | D03 Output Selection | Y13 Signal: Zero current detection to PLC (keypad or PC) | 113 |
331 | RS-485 communication station number | Modbus | 1 |
332 | RS-485 communication speed | Modbus | 384 |
333 | RS-485 communication stop bit length / data length | Modbus | 0 |
334 | RS-485 communication parity check selection | Modbus | 0 |
359 | Encoder rotation direction | CW or CCW | 1 |
368 | Feedback gain | Drive level PID | 1 |
369 | Number of encoder pulses | Motor Encoder resolution (vector mode) | 1024 |
374 | Overspeed detection level | Mitsu default | 9999 |
376 | Encoder signal loss detection enable/disable selection | Enabled | 1 |
414 | PLC function operation selection | PLC program to load (A700=1, A800=2) | 1 or 2 |
539 | Modbus Communication check time interval | No communication check (signal loss detection) | 9999 |
549 | Protocol selection | MODBUS RTU protocol | 1 |
550 | NET mode operation command source selection | The RS-485 terminals are the command source when in the PU | 1 |
800 | Control method selection | 0=Vector, 10=Sensorless Vector, 20=V/f | 0 |
802 | Pre-excitation selection | Servo lock | 1 |
820 | Speed control P gain 1 | Drive level PID | 20 |
1199 | PLC function user parameter 50 | open circuit detection | 50 |
C3 | Terminal 2 frequency setting bias | Making 0% = 0Hz See the instructions on setting the C3 value. | |
C4 | Terminal 2 Input Gain | Making sure 100% = 60Hz See the instructions on setting the C4 value. |
Stagehand Pro 2 Machine Specific Parameters
Spotline/Pushstick/Revolver
Pr. | Name | Setting |
---|---|---|
9 | Electronic thermal O/L relay/Rated motor current | 13.5 |
3 | Base frequency | 60 |
71 | Applied Motor | 3 |
80 | Motor Capacity (kw) | 3.7 |
81 | Motor Poles | 4 |
83 | Motor Voltage | 230 |
84 | Motor Frequency | 60 |
125 | Terminal 2 gain frequency | 60 |
359 | Motor encoder direction | 1 |
800 | Control method: 0=Vector, 10=Sensorless Vector, 20=V/f | 0 |
CM Smart Chain Hoist
Pr. | Name | Setting |
---|---|---|
9 | Electronic thermal O/L relay/Rated motor current | 13 |
1 | Maximum frequency | 110 |
3 | Base frequency | 106 |
71 | Applied Motor | 3 |
80 | Motor Capacity (kw) | 2.63 |
81 | Motor Poles | 4 |
83 | Motor Voltage | 230 |
84 | Motor Frequency | 106 |
125 | Terminal 2 gain frequency | 106 |
359 | Motor encoder direction | 0 |
800 | Control method: 0=Vector, 10=Sensorless Vector, 20=V/f | 0 |
Floorpocket Lift
Pr. | Name | Setting |
---|---|---|
9 | Electronic thermal O/L relay/Rated motor current | 17.5 |
1 | Maximum frequency | 80 |
3 | Base frequency | 60 |
71 | Applied Motor | 3 |
80 | Motor Capacity (kw) | 3.7 |
81 | Motor Poles | 4 |
83 | Motor Voltage | 230 |
84 | Motor Frequency | 60 |
125 | Terminal 2 gain frequency | 60 |
800 | Control method: 0=Vector, 10=Sensorless Vector, 20=V/f | 0 |