Pro+ Parameters

If after setting the following parameters and you are still having trouble, it's probably a good time to reset the VFD back to factory settings and start fresh.

Set Parameter 77 = 2 before jumping into manually entering parameters!

No.NameA800 ValuesA700 Values

0

Torque boost

4

-

1

Maximum frequency

120

120

2

Minimum frequency

0

0

3

Base frequency

60

60

7

Acceleration time

0.1

.1

8

Deceleration time

0.1

.1

9

Electronic thermal O/L relay/Rated motor current

17.5

17.5

10

DC injection brake operation frequency

0.5

.5

11

DC injection brake operation time

0.5

.5

12

DC injection brake operation voltage

4

4

13

Starting frequency

0.2

0.2

22

Stall prevention operation level (torque limit level)

200

200

30

Regenerative function selection

1

1

70

Special regenerative brake duty

10

10

71

Applied motor

3

3

72

PWM frequency selection

15

15

73

Analog input selection

1

1

77

Parameter write selection

2

2

79

Operation mode selection

2

2

80

Motor capacity

3.7

3.7

81

Number of motor poles

4

4

83

Rated motor voltage

230

230

84

Rated motor frequency

60

60

96

Auto tuning setting/status

0

0

117

PU communication station number

1

1

118

PU communication speed

384

384

119

PU communication stop bit length / data length

0

0

120

PU communication parity check

0

0

121

Number of PU communication retries

1

1

122

PU communication check time interval

9999

9999

125

Terminal 2 frequency setting gain frequency

60

60

145

PU display language selection

1

1

152

Zero current detection level

5

5

153

Zero current detection time

0.1

0.1

180

RL terminal function selection

9999

9999

181

RM terminal function selection

9999

9999

182

RH terminal function selection

50

50

187

MRS terminal function selection

9999

9999

189

RES terminal function selection

9999

9999

190

RUN terminal function selection

9999

9999

192

IPF terminal function selection

2

2

194

FU terminal function selection

9999

9999

195

ABC1 terminal function selection

199

199

252

Override Bias

100

100

316

D03 Output Selection Keypad programmable only

113

-

331

RS-485 communication station number

1

1

332

RS-485 communication speed

384

384

333

RS-485 communication stop bit length / data length

0

0

334

RS-485 communication parity check selection

0

0

359

Encoder rotation direction

1

1

369

Number of encoder pulses

1024

1024

374

Overspeed detection level

9999

9999

376

Encoder signal loss detection

1

1

414

PLC function operation

2

1

549

Protocol selection

1

1

550

NET mode operation command source selection

1

1

800

Control method selection

0

0

820

Speed control P gain 1

20

20

1199

PLC function user parameter 50

50

-

C3

Terminal 2 frequency setting bias See the instructions on setting the C3 value.

C4

Terminal 2 Input gain See the instructions on.