# Pro+ Parameters

If after setting the following parameters and you are still having trouble, it's probably a good time to [reset the VFD back to factory settings](https://docs.creativeconners.com/docs/stagehand/stagehand-parameters/all-clear-parameter-clear) and start fresh.

{% hint style="warning" %}
**Set Parameter 77 = 2 before jumping into manually entering parameters!**
{% endhint %}

<table data-full-width="false"><thead><tr><th>No.</th><th>Name</th><th>A800 Values</th><th>A700 Values</th><th data-hidden>Notes</th><th data-hidden>Initial value</th></tr></thead><tbody><tr><td>0</td><td>Torque boost</td><td>4</td><td>-</td><td>Compensate for low torque in V/f mode</td><td>4</td></tr><tr><td>1</td><td>Maximum frequency</td><td>120</td><td>120</td><td>Max frequency output from the VFD</td><td>120</td></tr><tr><td>2</td><td>Minimum frequency</td><td>0</td><td>0</td><td>Min frequency output from the VFD</td><td>0</td></tr><tr><td>3</td><td>Base frequency</td><td>60</td><td>60</td><td>From motor nameplate</td><td>60</td></tr><tr><td>7</td><td>Acceleration time</td><td>0.1</td><td>.1</td><td>Drive level - not used</td><td>5</td></tr><tr><td>8</td><td>Deceleration time</td><td>0.1</td><td>.1</td><td>Drive level - not used</td><td>5</td></tr><tr><td>9</td><td>Electronic thermal O/L relay/Rated motor current</td><td>17.5</td><td>17.5</td><td>From motor nameplate</td><td>17.5</td></tr><tr><td>10</td><td>DC injection brake operation frequency</td><td>0.5</td><td>.5</td><td>Hz level when the VFD will apply the DC injection braking</td><td>3</td></tr><tr><td>11</td><td>DC injection brake operation time</td><td>0.5</td><td>.5</td><td>DC injection brake timing</td><td>0.5</td></tr><tr><td>12</td><td>DC injection brake operation voltage</td><td>4</td><td>4</td><td>Voltage applied (% of input voltage)</td><td>4</td></tr><tr><td>13</td><td>Starting frequency</td><td>0.2</td><td>0.2</td><td>VFD will not start below this value</td><td>0.5</td></tr><tr><td>22</td><td>Stall prevention operation level (torque limit level)</td><td>200</td><td>200</td><td></td><td></td></tr><tr><td>30</td><td>Regenerative function selection</td><td>1</td><td>1</td><td>Brake resistor installed</td><td>0</td></tr><tr><td>70</td><td>Special regenerative brake duty</td><td>10</td><td>10</td><td>Based on braking resistor installed</td><td>0</td></tr><tr><td>71</td><td>Applied motor</td><td>3</td><td>3</td><td>3 = Induction motor</td><td>0</td></tr><tr><td>72</td><td>PWM frequency selection</td><td>15</td><td>15</td><td>Performance &#x26; noise</td><td>1</td></tr><tr><td>73</td><td>Analog input selection</td><td>1</td><td>1</td><td>0-5VDC</td><td>1</td></tr><tr><td>77</td><td>Parameter write selection</td><td>2</td><td>2</td><td>enabled across all states</td><td>0</td></tr><tr><td>79</td><td>Operation mode selection</td><td>2</td><td>2</td><td>External operation</td><td>0</td></tr><tr><td>80</td><td>Motor capacity</td><td>3.7</td><td>3.7</td><td>From motor nameplate</td><td>9999</td></tr><tr><td>81</td><td>Number of motor poles</td><td>4</td><td>4</td><td>Nameplate motor RPM 2=3500rpm, 4=1750rpm, 6=1150rpm</td><td>9999</td></tr><tr><td>83</td><td>Rated motor voltage</td><td>230</td><td>230</td><td>From motor nameplate</td><td>200</td></tr><tr><td>84</td><td>Rated motor frequency</td><td>60</td><td>60</td><td>From motor nameplate</td><td>9999</td></tr><tr><td>96</td><td>Auto tuning setting/status</td><td>0</td><td>0</td><td></td><td>0</td></tr><tr><td>117</td><td>PU communication station number</td><td>1</td><td>1</td><td>Modbus</td><td>0</td></tr><tr><td>118</td><td>PU communication speed</td><td>384</td><td>384</td><td>Modbus</td><td>192</td></tr><tr><td>119</td><td>PU communication stop bit length / data length</td><td>0</td><td>0</td><td>Modbus</td><td>1</td></tr><tr><td>120</td><td>PU communication parity check</td><td>0</td><td>0</td><td>Modbus</td><td>2</td></tr><tr><td>121</td><td>Number of PU communication retries</td><td>1</td><td>1</td><td>Modbus</td><td>1</td></tr><tr><td>122</td><td>PU communication check time interval</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>125</td><td>Terminal 2 frequency setting gain frequency</td><td>60</td><td>60</td><td>Set what 100% = in hertz (overspeed)</td><td>60</td></tr><tr><td>145</td><td>PU display language selection</td><td>1</td><td>1</td><td></td><td></td></tr><tr><td>152</td><td>Zero current detection level</td><td>5</td><td>5</td><td></td><td></td></tr><tr><td>153</td><td>Zero current detection time</td><td>0.1</td><td>0.1</td><td></td><td></td></tr><tr><td>180</td><td>RL terminal function selection</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>181</td><td>RM terminal function selection</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>182</td><td>RH terminal function selection</td><td>50</td><td>50</td><td></td><td></td></tr><tr><td>187</td><td>MRS terminal function selection</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>189</td><td>RES terminal function selection</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>190</td><td>RUN terminal function selection</td><td>9999</td><td>9999</td><td>I/O</td><td>0</td></tr><tr><td>192</td><td>IPF terminal function selection</td><td>2</td><td>2</td><td>I/O</td><td>2</td></tr><tr><td>194</td><td>FU terminal function selection</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>195</td><td>ABC1 terminal function selection</td><td>199</td><td>199</td><td></td><td></td></tr><tr><td>252</td><td>Override Bias</td><td>100</td><td>100</td><td>old school overspeed</td><td>50</td></tr><tr><td>316</td><td>D03 Output Selection<br><strong>Keypad programmable only</strong></td><td>113</td><td>-</td><td></td><td></td></tr><tr><td>331</td><td>RS-485 communication station number</td><td>1</td><td>1</td><td>Modbus</td><td>0</td></tr><tr><td>332</td><td>RS-485 communication speed</td><td>384</td><td>384</td><td>Modbus</td><td>96</td></tr><tr><td>333</td><td>RS-485 communication stop bit length / data length</td><td>0</td><td>0</td><td>Modbus</td><td>1</td></tr><tr><td>334</td><td>RS-485 communication parity check selection</td><td>0</td><td>0</td><td>Modbus</td><td>2</td></tr><tr><td>359</td><td>Encoder rotation direction</td><td>1</td><td>1</td><td></td><td></td></tr><tr><td>369</td><td>Number of encoder pulses</td><td>1024</td><td>1024</td><td></td><td></td></tr><tr><td>374</td><td>Overspeed detection level</td><td>9999</td><td>9999</td><td></td><td></td></tr><tr><td>376</td><td>Encoder signal loss detection</td><td>1</td><td>1</td><td></td><td></td></tr><tr><td>414</td><td>PLC function operation</td><td>2</td><td>1</td><td></td><td></td></tr><tr><td>549</td><td>Protocol selection</td><td>1</td><td>1</td><td>MODBUS RTU protocol</td><td>0</td></tr><tr><td>550</td><td>NET mode operation command source selection</td><td>1</td><td>1</td><td></td><td>9999</td></tr><tr><td>800</td><td>Control method selection</td><td>0</td><td>0</td><td>10=Sensorless Vector, 20=Magnetic Flux Vector or V/f</td><td>20</td></tr><tr><td>820</td><td>Speed control P gain 1</td><td>20</td><td>20</td><td>Drive level PID</td><td>60</td></tr><tr><td>1199</td><td>PLC function user parameter 50</td><td>50</td><td>-</td><td></td><td></td></tr><tr><td>C3</td><td>Terminal 2 frequency setting bias<br><a href="https://docs.creativeconners.com/docs/stagehand/stagehand-parameters/setting-the-c3-value">See the instructions on setting the C3 value.</a></td><td><a href="setting-the-c3-value">TBD</a></td><td><a href="setting-the-c3-value">TBD</a></td><td>Making 0% = 0Hz</td><td>0.00</td></tr><tr><td>C4</td><td>Terminal 2 Input gain<br><a href="setting-the-c4-value">See the instructions on.</a></td><td><a href="setting-the-c4-value">TBD</a></td><td><a href="setting-the-c4-value">TBD</a></td><td>Making sure 100% = 60Hz See the instructions on <a href="setting-the-c4-value">setting the C4 value</a>.</td><td>100</td></tr></tbody></table>