Docs
Download Spikemark
  • Creative Conners Docs
  • Technical Support
    • Tech Tips
      • Revolver V1 Position Issues
      • Setting Up a New Comptuer for Spikemark
  • Spikemark 6
    • Navigating Spikemark
      • Show Modes
      • Workspaces
        • Jog Workspace
        • Cues Workspace
        • Preset Workspace
        • Customize Your Workspace
      • Selection and Input
      • Tags
      • Filters
      • Search
      • Keyboard Shortcuts
    • Cues
      • Cue Structure
      • Cue Creation
        • Add Movements
        • Add Triggers
        • Add Actions
      • Editing Cue Properties
      • Cue Deletion
    • Movements
      • Motor Movements
      • Locked Group Movements
      • Unlocked Group Movements
      • FX Movements
      • OSC Movements
        • Custom OSC Command Library
      • UDP Movements
      • Modbus Movements
    • Triggers
      • Playback Go Trigger
      • Delay Trigger
      • Completion Trigger
      • Position Trigger
      • FX Input Trigger
      • Stacking Triggers
    • Actions
      • Motor Property Action
      • Motor Method Action
      • Playback Property Action
    • Running Cues
      • Playbacks
        • Playback Editing
        • Playback Control Speed
        • Playback Stacking
      • Cue Controls
      • Consolette
      • Restore Cue
    • Spikes
      • Simple Spikes
      • Dynamic Spikes
        • Incremental Spikes
        • Nearest Forward Multiple Spikes
        • Nearest Reverse Multiple Spikes
        • Nearest Multiple Spikes
      • Locked Group Spikes
    • Presets
      • Presets Overview
      • Creating, Editing, and Deleting Presets
      • Running Presets
    • User Authentication and Authorization
      • Overview
      • Users
      • Roles
      • Permissions
    • Show Control
      • Open Sound Control (OSC)
        • Send OSC Messages
        • OSC Position Output
        • OSC Input Trigger
          • OSC Input Messages
          • Cue Messages
          • Playback Messages
          • Sequence Step Messages
          • Motor Movement Messages
          • Motor Messages
        • Troubleshooting OSC
          • OSC Response Window
          • Medialon Manager Configuration
      • UDP
        • Send UDP Messages
        • UDP Position Output
      • Watchout Position Output
      • PosiStageNet (PSN)
  • Spikemark 5
    • How to Open Spikemark
    • Spikemark Installation
      • User Authorization
      • Windows Settings
    • Quick Start Tutorial
      • Step 1: Adding Motors
        • 1.1 Simulator Mode
        • 1.2 Add Motors from the Machine Library
        • 1.3 Rename Motors
        • 1.4 Add A Group
      • Step 2: Saving
      • Step 3: Jogging
        • 3.1 Single Axis Jogging
        • 3.2 Jogging Multiple Machines (Multi-Jog)
        • 3.3 Move To Position
      • Step 4: Writing Your First Cues
        • 4.1 Cues Workspace
        • 4.2 Add A Movement
        • 4.3 Duplicate A Cue
        • 4.4 Delete A Movement From A Cue
        • 4.5 Edit Movement - Changing Position, Speed, and Time
        • 4.6 Copy to Group
        • 4.7 Cue Total Time
        • 4.8 Load and Run your Cue
        • 4.9 Spikes
        • 4.10 Cue Links
        • 4.11 Restore Cue
        • 4.12 Delete A Cue
      • Step 5: Going Live
        • 5.1 Set Your IP Address
        • 5.2 Test Manual Movement
        • 5.3 Resetting Position
        • 5.4 Program Your Show
      • Sharpen Your Programming Skills
    • Steps to a Successful Load-In
    • Show Modes
    • Locking Changes
    • Workspaces
      • Customize Your Workspace
    • Selection and Input
    • IP Address and Network Connection
      • Setting Computer IP Address
      • Setting Stagehand IP Address
      • Setting Showstopper Consolette IP Address
      • Setting Pendant IP Address
      • Setting Showstopper IP Address
      • Setting Showstopper Node ID
      • Connecting To A Stagehand
      • Connecting To A Showstopper Consolette
      • Connecting To A Pendant
    • Adding Motors or Machines
      • Adding Motors or Machines From The Machine Library
      • Adding Custom Motors or Machines To Spikemark
      • Importing Motors or Machines
      • Exporting Motors or Machines
    • Stage Model Viewer
      • Changing Your Viewer
      • Adjusting the Stage Size
      • Changing the Type of Scenery
      • Adjusting Model Dimensions
      • Adjusting Model Rotation
      • Adjusting Location On Stage
      • Making Models
        • Modeling A Winch
        • Modeling A Lift
        • Modeling A Hoist
        • Modeling A Vertical Curtain
        • Modeling A Split Curtain
        • Modeling A Turntable or Periaktos
    • Tags
    • Editing Direction Labels
    • Filters
    • Search
    • Position
      • Reset Position
      • Units
      • Position Scale
        • Position Scale Wizard
        • Manually Calculate Position Scale
      • Limits
        • Setting Hard Limits
        • Setting Soft Limits
      • Target Tolerance
      • Strict Timing Mode
      • Position Fault and Max Position Error
      • Motor Tuning Overview
        • Motor Tuning - The Practical Approach
    • Load Cell
      • Load Cell Readout
      • Load Cell Configuration
      • Load Cells and Groups
    • Speed
    • Spikes
      • Adding A Spike
      • Removing A Spike
      • Spike Input Fields
      • Simple Spike
      • Incremental Spike
      • Nearest Forward Multiple Spike
      • Nearest Reverse Multiple Spike
      • Nearest Multiple Spike
    • Editing Cues
      • Adding and Deleting Cues
      • Adding and Deleting Movements
      • Edit Movement
      • Edit Cue Options
    • Cue Controls
    • Cue Status
    • Cue Links
      • Completion Link
      • Time Link
      • Position Link
      • Input Link
      • Deleting A Cue Link
    • Presets
    • Motor Groups
    • Showstopper Node Editor
    • Show Control
      • Open Sound Control (OSC)
        • OSC Position Output
        • OSC Messenger
          • Expanding The Command Library
        • OSC Response Window
        • OSC Input Trigger
          • Input Messages
          • Cue Commands
          • Motor Commands
          • My OSC Input Trigger Isn't Working, Is there another way?
      • UDP
        • UDP Position Output
        • UDP Messenger
      • Watchout Position Output
      • Modbus Effect
      • PosiStageNet (PSN)
    • Drive Communication
      • Drive Information
      • Configuring The Drive
      • Analyzing Movements
      • Drive Communication: Compatibility
      • Drive Communication: Setting VFD Parameters
      • RS-485 Upgrade
        • Upgrading an A800
        • Upgrading an A700
        • Drive Communication Troubleshooting
      • VFD Fault Codes
    • Motor Status Icons
    • Keyboard Shortcuts
    • Advanced Cue Techniques
  • Showstopper
    • Showstopper 4 Base
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Spikemark Console
      • Making-The-Connections
      • Using-the-Console
      • Console-Firmware
      • Troubleshooting
      • Specifications
    • Spikemark Pendant V2
      • Getting Started
      • Setup
      • Operation
      • Troubleshooting
      • Specifications
      • Drawings
    • Showstopper 4 E-Stop Hub
      • Getting Started
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper 4 Accessory Hub
      • Getting Started
      • Installation
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper Remote E-Stop
      • Installation
      • Making The Connections
      • Operation
      • Troubleshooting
      • Specifications
    • Control Connection
      • Installation
      • Making The connections
      • Operation
      • Troubleshooting
      • Specifications
    • Drive Connection
      • Installation
      • Making The connections
      • Operation
      • Troubleshooting
      • Specifications
    • Showstopper E-Stop Patch Panel
    • Showstopper Accessory Patch Panel
    • 🦺Safety Interlock
      • Safety Interlock Classic
      • Safety Interlock Pro
      • Safety Interlock Pro 4
      • 4-Axis Safety Interlock
    • Legacy
      • Showstopper 3 Base
      • Showstopper 3 Remote
      • Showstopper 3 E-Stop Patch Panel
      • Stage Manager
        • Getting Started
        • Installation
        • Making the Connections
        • Operation
        • Troubleshooting
        • Specifications
      • Showstopper 4 Consolette
        • Features
        • Making the Connections
          • Accessory Cable Connection
          • Ethernet Connection
          • Multiple Consolettes
        • On-Board Settings
        • Operation & Spikemark Integration
        • Connecting the Consolette to Spikemark
        • Jogging Motors
        • Running Cues
        • Emergency Stop
        • Updating Consolette Firmware
        • Troubleshooting
        • Physical Specifications
        • Drawings
  • Stagehand
    • Stagehand Firmware
      • Manually Updating a Stagehand Unipolar V6 Card via SD Card
      • Manually Updating a Stagehand Unipolar V6 Card via USB
    • Stagehand Parameters
      • Stagehand Pro 2 Parameters
      • Stagehand Pro 3/Pro 4 Parameters
      • Stagehand Pro 3e Parameters
      • Stagehand Pro 5 Parameters
      • Stagehand Apprentice 2 Parameters
      • Stagehand Apprentice
      • Stagehand AC - AKA: The Classic
      • Classic+ Parameters
      • Pro+ Parameters
      • Setting the C3 Value
      • Setting the C4 Value
      • All Clear/Parameter Clear
      • How to Use the Mitsubishi VFD Keypad
      • USB Parameter Sets
      • Parameter Library in Spikemark
    • Stagehand Apprentice
      • Getting Started
      • Installing the Stagehand
      • Making the Connections
      • Hooking up a motorized effect
      • Using the Stagehand
      • Troubleshooting
      • Technical Support
      • Specifications
    • Stagehand Apprentice DC
    • Stagehand Apprentice 2
      • Stagehand Apprentice 2: Features
      • Stagehand Apprentice 2: Installation
      • Stagehand Apprentice 2: Making The Connections
        • Stagehand Apprentice 2: Power Input
        • Stagehand Apprentice 2: Motor and Brake Output
        • Stagehand Apprentice 2: Sensor Input
        • Stagehand Apprentice 2: Interlock Inputs
        • Stagehand Apprentice 2: Ethernet Input
        • Stagehand Apprentice 2: Showstopper Emergency Stop Input
      • Stagehand Apprentice 2: Operation
      • Stagehand Apprentice 2: Troubleshooting
      • Stagehand Apprentice 2 Specifications
      • Stagehand Apprentice 2: Drawings
    • Stagehand FX
      • Getting Started
      • Making the Connections
      • Connecting an Effect
      • Operation
      • Troubleshooting
      • Specifications
    • Stagehand Hydraulic
      • Getting Started
      • Features
      • Installation
      • Operation
      • Troubleshooting
      • Technical Support
      • Specifications
      • Drawings
    • Stagehand Pro 3
    • Stagehand Pro 3E
    • Stagehand Pro 4
      • Stagehand Pro 4: Unpacking
      • Stagehand Pro 4: Installation
      • Stagehand Pro 4: Making The Connections
        • Stagehand Pro 4: Power Input
        • Stagehand Pro 4: Motor and Brake Output
        • Stagehand Pro 4: Sensor Input
        • Stagehand Pro 4: Interlock Inputs
        • Stagehand Pro 4: Ethernet Input
        • Stagehand Pro 4: Showstopper Emergency Stop Input
      • Stagehand Pro 4: Operation
        • Stagehand Pro 4: Powering Up
        • Stagehand 4: Machine Configuration
        • Stagehand Pro 4: Manual Operation (Jogging)
        • Stagehand Pro 4: Brake Test
        • Stagehand Pro 4: Connecting to Spikemark
        • Stagehand Pro 4: Status Displays
      • Stagehand Pro 4: Troubleshooting
        • Stagehand Pro 4: Recovering From Faults
        • Stagehand Pro 4: Monitoring Behavior
      • Stagehand Pro 4: Specifications
      • Stagehand Pro 4: Drawings
    • Stagehand Pro 5
      • Stagehand Pro 5: Features
      • Stagehand Pro 5: Installation
      • Stagehand Pro 5: Making The Connections
        • Stagehand Pro 5: Power Input
        • Stagehand Pro 5: Motor and Brake Output
        • Stagehand Pro 5: Sensor Input
        • Stagehand Pro 5: Interlock Inputs
        • Stagehand Pro 5: Ethernet Input
        • Stagehand Pro 5: Showstopper Emergency Stop Input
      • Stagehand Pro 5: Operation
      • Stagehand Pro 5: Troubleshooting
      • Stagehand Pro 5 Specifications
      • Stagehand Pro 5: Drawings
      • Stagehand Pro 5: Replace Control Card
    • Deck Chief 2
      • Getting Started
      • Features
      • Making the Connections
      • Using the Deck Chief
      • Troubleshooting
      • Specifications
    • Stagehand Classic+
    • Stagehand Pro+
    • Legacy Manuals
      • Deck Chief
        • Getting Started
        • Installation
        • Making the Connections
        • Using the Deck Chief
        • Troubleshooting
        • Specifications
        • Deck Chief Legacy Connections
      • Stagehand Mini^2
      • Stagehand Pro AC (Pro 2)
      • Stagehand AC
      • Stagehand Mini
      • Stagehand DC & DC Max
    • X-Groove Override
  • Machinery
    • Smart Chain Hoist
      • Getting Started
      • Installation
      • Making the Connections
      • Under The Hood
      • Troubleshooting
      • Specifications
    • Floorpocket
      • GettingStarted
      • Installation
      • Making the Connections
      • Prepping the Machine for Operation
      • VFD Settings
      • Troubleshooting
      • Specifications
    • Floorpocket v2
      • Get Started
        • Unpack
        • Installation Tools
      • Assembly
        • Base
        • Column Extension
        • Limit Cables
        • Roller Chain
      • Get Moving
        • Power Up
        • Platform
        • Stay Safe
        • Write Cues
      • Maintain the Machine
      • Troubleshooting
      • Floorpocket v2: Specifications
    • Pivot
      • Getting Started
      • Installation
      • Troubleshooting
      • Specifications
    • Pushstick
      • Getting Started
      • Installation
      • Making the Connections
      • Rigging the Pushstick
        • Rigging a Pushstick v2
      • Setting the Limits
      • Troubleshooting
      • Specifications
    • Pushstick Mini
      • Getting Started
      • Installation
      • Making the Connections
      • Rigging the Pushstick Mini
      • Troubleshooting
      • Technical Support
      • Specifications
    • Revolver
      • Installation
      • Making the Connections
      • Making It Move
        • Friction Wheel Tension Guide
      • Position Scaling
        • Encoder Finessing
      • Troubleshooting
      • Specifications
        • Drawing
      • Multi-Motor Configuration
      • Revolver v1 Manual
    • Rotator
      • Getting Started
      • Installation
      • Making the Connections
      • Troubleshooting
      • Technical Support
      • Specifications
    • Spotline
      • Getting Started
      • Installation
      • Rigging the Spotline
      • Operation
      • Troubleshooting
      • Specifications
    • Spotline V2
      • Spotline V2: Setup Process
      • Spotline V2: Installation
      • Spotline V2: Rigging the Spotline
      • Spotline V2: Operation
      • Spotline V2: Troubleshooting
      • Spotline V2 Accessories
      • Spotline V2: Maintenance
      • Spotline V2: Specifications
    • Spotline Mini v2
    • Spotline Practical
      • Practical v2
        • Getting Started
        • Installation
        • Rigging the Machine
        • Setting the Limits
        • Troubleshooting
        • Specifications
      • Practical v1
        • Getting Started
        • Installation
        • Operation
        • Troubleshooting
        • Specifications
    • Turntable Template
      • Overview
      • Bill Of Materials
      • Fabrication
      • Turntable Assembly and Installation
      • Turntable Assembly Guide
      • Tech Support
      • 20' Turntable Specs
      • Turtable Research Notes for Nerds
    • Retired
      • Curtain Call
      • Trickline
        • TricklineProductManualv1.0
        • Getting Started
        • Installation
        • Making the Connections
        • Troubleshooting
        • Specifications
      • Spotline Mini
        • Getting Started
        • Installation
        • Making the Connections
        • Rigging the Spotline Mini
        • Troubleshooting
        • Specifications
      • Pushstick Manual
    • Stromag Limits
  • Broadweigh Load Cells
Powered by GitBook
On this page
  • Physical Specification
  • Electrical Specifications

Was this helpful?

  1. Stagehand
  2. Stagehand Apprentice 2

Stagehand Apprentice 2 Specifications

Physical Specification

Description

Value

Dimensions

19”(W) x 20”(D) x 10.5”(H)

Rack Unit Height

6U

Weight

52lbs

Shipping Dimensions

24”x24”x18”

Shipping Weight

62lbs

Electrical Specifications

Description

1HP D700

5HP E800

5HP 460V E800

UL Listed

Conforms with UL508a Standard for Industrial Control Panels

Conforms with UL508a Standard for Industrial Control Panels

Conforms with UL508a Standard for Industrial Control Panels

Input Voltage

Single Phase 120VAC 50/60Hz

3 Phase 200-240VAC 50/60hz

3 Phase 380-480VAC 50/60hz

Max Current Draw

20A

30A

18A

Motor Output Voltage

230VAC

230VAC

460VAC

Min Motor Output

1/4HP

2Hp

5.5HP

Max Motor Output

1HP

5HP

7.5HP

Min Motor Speed

0.5Hz

0.5Hz

0.5Hz

Max Motor Speed

120Hz

120Hz

120Hz

Brake Output

1 Phase 115VAC 50/60Hz

1 Phase 200-240VAC 50/60Hz

1 Phase 380-480VAC 50/60Hz

Max Brake Output Current

2A

6A

6A

Emergency Stop Input Voltage

24VDC

24VDC

24VDC

Emergency Stop Input Current

85mA

85mA

85mA

Limit Switch Voltage

24VDC

24VDC

24VDC

Limit Switch Current

10mA

10mA

10mA

Limit Switch Signal Type

dry contact / potential free

dry contact / potential free

dry contact / potential free

Cross-Groove Switch Voltage

24VDC

24VDC

24VDC

Position Encoder Voltage

12

12VDC

12VDC

Position Encoder Type

Incremental, Quadrature, Line Driven

Incremental, Quadrature, Line Driven

Incremental, Quadrature, Line Driven

Max Encoder Current

1A

1A

1A

Interlock Switch Voltage

24VDC

24VDC

24VDC

Interlock Switch Current

10mA

10mA

10mA

Interlock Signal Type

dry contact / potential free

Dry contact / potential free

Dry contact / potential free

Network Input

10Base-T Ethernet

10Base-T Ethernet

10Base-T Ethernet

Commissioning Port

USB-B

USB-B

USB-B

24VDC Control Circuit Fuse

1A Medium-Acting 5mm x 20mm

Littelfuse 0234001.MXP

1A Medium-Acting 5mm x 20mm

Littelfuse 0234001.MXP

2.5A Medium-Acting 5mm x 20mm

Littelfuse 023402.5MXP

5.5VDC Control Circuit Fuse

1A Medium-Acting 5mm x 20mm

Littelfuse 0234001.MXP

1A Medium-Acting 5mm x 20mm

Littelfuse 0234001.MXP

1A Medium-Acting 5mm x 20mm

Littelfuse 0234001.MXP