> For the complete documentation index, see [llms.txt](https://docs.creativeconners.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.creativeconners.com/docs/stagehand/stagehand-apprentice/specifications.md).

# Specifications

## Physical Specifications <a href="#h.ihv636" id="h.ihv636"></a>

<table data-header-hidden><thead><tr><th></th><th width="128"></th><th></th><th></th><th></th></tr></thead><tbody><tr><td></td><td>Height</td><td>Width</td><td>Depth</td><td>Weight</td></tr><tr><td>Stagehand Apprentice<br>With handles and feet</td><td>10-5/8”</td><td>14”</td><td>13-1/4”</td><td>26lbs</td></tr><tr><td>Stagehand Apprentice<br>With Rack Ears</td><td>8-3/4”</td><td>19”</td><td>13-1/4”</td><td>28.5lbs</td></tr><tr><td>Shipping Specifications</td><td>14-1/2”</td><td>16-3/4”</td><td>18-1/4”</td><td>35lbs</td></tr></tbody></table>

![Stagehand Apprentice Overview](/files/Ubve6WCquGcQNnqtLa9J)

## Electrical Specifications <a href="#h.1hmsyys" id="h.1hmsyys"></a>

| **Input Voltage**                  | **120VAC, single phase**                                                                                                                                                        | **208VAC, three phase**                                                                                                                                                         |
| ---------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Max Input Current                  | <p>20 amps.<br>Supply proper branch circuit protection using UL Class T fuses or a Listed UL 489 Molded Case Circuit Breaker (MCCB) with a maximum allowable rating of 20A.</p> | <p>30 amps.<br>Supply proper branch circuit protection using UL Class T fuses or a Listed UL 489 Molded Case Circuit Breaker (MCCB) with a maximum allowable rating of 30A.</p> |
| Integrated VFD                     | FR-D710W-042                                                                                                                                                                    | FR-D720-165                                                                                                                                                                     |
| Motor Output Voltage               | 230VAC 0.2Hz-60Hz                                                                                                                                                               | 230VAC 0.2Hz-60Hz                                                                                                                                                               |
| Max Motor Output                   | 1HP                                                                                                                                                                             | 5HP                                                                                                                                                                             |
| Min Motor Output                   | 1/2HP                                                                                                                                                                           | 2HP                                                                                                                                                                             |
| Minimum Motor Speed                | .5Hz                                                                                                                                                                            | .5Hz                                                                                                                                                                            |
| Maximum Motor Speed                | 60Hz                                                                                                                                                                            | 60Hz                                                                                                                                                                            |
|                                    | Overspeed motor by adjusting Parameters 125 and 903                                                                                                                             |                                                                                                                                                                                 |
| Motor Brake Voltage                | 120VAC 50/60Hz                                                                                                                                                                  | 220VAC 50/60Hz                                                                                                                                                                  |
| Motor Brake Output Current         | 10A Max                                                                                                                                                                         | 5A Max                                                                                                                                                                          |
| Emergency Stop Input Voltage       | 24VDC                                                                                                                                                                           | 24VDC                                                                                                                                                                           |
| Emergency Stop Input Current       | 520mA                                                                                                                                                                           | 520mA                                                                                                                                                                           |
| Forward Limit Switch Voltage       | 12VDC                                                                                                                                                                           | 12VDC                                                                                                                                                                           |
| Forward Limit Switch Current       | 10mA                                                                                                                                                                            | 10mA                                                                                                                                                                            |
| Forward Limit Switch Contact Type  | Normally Closed (N.C.) dry contact                                                                                                                                              | Normally Closed (N.C.) dry contact                                                                                                                                              |
| Reverse Limit Switch Voltage       | 12VDC                                                                                                                                                                           | 12VDC                                                                                                                                                                           |
| Reverse Limit Switch Current       | 10mA                                                                                                                                                                            | 10mA                                                                                                                                                                            |
| Reverse Limit Switch Contact Type  | Normally Closed (N.C.) dry contact                                                                                                                                              | Normally Closed (N.C.) dry contact                                                                                                                                              |
| Ultimate Limit Switch Voltage      | 12VDC                                                                                                                                                                           | 12VDC                                                                                                                                                                           |
| Ultimate Limit Switch Current      | 10mA                                                                                                                                                                            | 10mA                                                                                                                                                                            |
| Ultimate Limit Switch Contact Type | Normally Closed (N.C.) dry contact                                                                                                                                              | Normally Closed (N.C.) dry contact                                                                                                                                              |
|                                    | Ultimate limit circuit is bypassed internally. Contact <support@creativeconners.com> if Ultimate limits are required.                                                           |                                                                                                                                                                                 |
| Control Input                      | 10Base-T Ethernet                                                                                                                                                               | 10Base-T Ethernet                                                                                                                                                               |
| Position Encoder Input             | 12VDC Quadrature encoder with differential line driver                                                                                                                          | 12VDC Quadrature encoder with differential line driver                                                                                                                          |
| Encoder Power Supply Voltage       | 12VDC                                                                                                                                                                           | 12VDC                                                                                                                                                                           |
| Maximum Encoder Position           | 1,073,741,823 counts                                                                                                                                                            | 1,073,741,823 counts                                                                                                                                                            |
| Minimum Encoder Position           | -1,073,741,824 counts                                                                                                                                                           | -1,073,741,824 counts                                                                                                                                                           |
| Maximum Encoder Velocity           | 15,999,023 counts/second                                                                                                                                                        | 15,999,023 counts/second                                                                                                                                                        |
| Maximum Acceleration               | 15,999,023 counts/second/second                                                                                                                                                 | 15,999,023 counts/second/second                                                                                                                                                 |

## Drawings

{% file src="/files/uZTjxulduJgwHmUzMdZo" %}

{% file src="/files/FYVONx8g2zPgum1Jg4x3" %}

{% file src="/files/RT4Q2zCDtuO7OIV37oH2" %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.creativeconners.com/docs/stagehand/stagehand-apprentice/specifications.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.