Drive Communication: Setting VFD Parameters
Use the tabs below for instructions on updating your Drive Communication VFD Parameters
On the VFD Keypad:
For Drive Communication, scroll to parameter 118
For Drive Communication, scroll to parameter 332
Repeat the steps above and make sure all the parameters listed below are set to the correct value too.
Lastly, cycle power to your Stagehand
Drive Communication VFD Parameter Values
Parameters for compatibility with Spikemark 5
Parameter | Description | Pro | Apprentice |
79 | Operation mode selection | 0 | 0 |
117 | PU communication station number | 1 | 1 |
118 | PU communication speed | 384 | 384 |
119 | PU communication stop bit length | 0 | 0 |
120 | PU communication parity check | 0 | 0 |
331 | RS-485 communication station number | 1 | N/A |
332 | RS-485 communication speed | 384 | N/A |
334 | RS-485 communication parity check selection | 0 | N/A |
338 | Communication operation command source | 0 | 0 |
339 | Communication speed command source | 0 | 0 |
340 | Communication startup mode selection | 0 | 0 |
549 | Protocol selection | 1 | 1 |
550 | NET mode operation command source selection | 1 | 1 |
551 | PU mode operation command source selection | 9999 | 9999 |