> For the complete documentation index, see [llms.txt](https://docs.creativeconners.com/docs/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.creativeconners.com/docs/stagehand/stagehand-pro-6/stagehand-pro-6-specs.md).

# Stagehand Pro 6: Specifications

## Physcal Specifications

|       Model       | Dimensions (W x D x H) | Rack Unit Height | Weight | Shipping Dimensions (W x D x H) | Shipping Weight |
| :---------------: | :--------------------: | :--------------: | :----: | :-----------------------------: | :-------------: |
|  SHPAC-6-208-3HP  |     19” x 17” x 7”     |        4U        |  52lbs |                                 |      62lbs      |
|  SHPAC-6-208-5HP  |     19” x 17” x 7”     |        4U        |  52lbs |                                 |      62lbs      |
| SHPAC-6-208-7.5HP |     19” x 17” x 14”    |        8U        |  65lbs |                                 |      75lbs      |
|  SHPAC-6-208-10HP |     19” x 17” x 14”    |        8U        |  65lbs |                                 |      75lbs      |
|  SHPAC-6-480-3HP  |    19” x 17” x 8.75”   |        5U        |  52lbs |                                 |      62lbs      |
|  SHPAC-6-480-5HP  |    19” x 17” x 8.75”   |        5U        |  52lbs |                                 |      62lbs      |
| SHPAC-6-480-7.5HP |    19” x 20” x 8.75”   |        5U        |  65lbs |                                 |      75lbs      |
|  SHPAC-6-480-10HP |    19” x 20” x 8.75”   |        5U        |  65lbs |                                 |      75lbs      |

## Electrical Specifications

### Common Specifications

| Description                                       | Value                                                                                    |
| ------------------------------------------------- | ---------------------------------------------------------------------------------------- |
| UL Listed                                         | Conforms with UL508a Standard for Industrial Control Panels                              |
| CSA Listed                                        | Conforms with CSA STD C22.2 NO 286 Standard for industrial control panels and assemblies |
| Min Motor Output                                  | Half of rated power                                                                      |
| Min Motor Speed                                   | 0.5Hz                                                                                    |
| Max Motor Speed                                   | 120Hz                                                                                    |
| Max Brake(Motor and Load Combined) Output Current | 6A                                                                                       |
| Emergency Stop Input Voltage                      | 24VDC                                                                                    |
| Emergency Stop Input Current                      | 85mA                                                                                     |
| Limit Switch Voltage                              | 24VDC                                                                                    |
| Limit Switch Current                              | 10mA                                                                                     |
| Limit Switch Signal Type                          | dry contact / potential free                                                             |
| Cross-Groove Switch Voltage                       | 24VDC                                                                                    |
| Cross-Groove Switch Current                       | 10mA                                                                                     |
| Cross-Groove Signal Type                          | dry contact / potential free                                                             |
| Load Cell Voltage                                 | 24VDC                                                                                    |
| Load Cell Signal                                  | 4-20mA Analog Signal                                                                     |
| Speed Encoder Voltage                             | 5VDC                                                                                     |
| Speed Encoder Type                                | Incremental, Quadrature, Line Driven                                                     |
| Position Encoder Voltage                          | 5VDC                                                                                     |
| Position Encoder Type                             | Incremental, Quadrature, Line Driven                                                     |
| Max Encoder(Speed and Position Combined) Current  | 1A                                                                                       |
| Interlock Switch Voltage                          | 24VDC                                                                                    |
| Interlock Switch Current                          | 10mA                                                                                     |
| Interlock Signal Type                             | Dry contact / potential free                                                             |
| Network Input                                     | 10Base-T Ethernet                                                                        |
| Commissioning Port                                | USB-B                                                                                    |
| 24VDC Control Circuit Fuse                        | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>                          |
| 5.5VDC Control Circuit Fuse                       | <p>1A Medium-Acting 5mm x 20mm</p><p>Littelfuse 0234001.MXP</p>                          |

### Input Power Specifications

| Model             | HP     | Input Voltage   | Circuit                   | Input Current | Input Connector |
| ----------------- | ------ | --------------- | ------------------------- | ------------- | --------------- |
| SHPAC-6-208-3HP   | 3 HP   | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 15.7A         | NEMA L15-20     |
| SHPAC-6-208-3HP   | 3 HP   | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 15.7A         | NEMA L21-20     |
| SHPAC-6-208-5HP   | 5 HP   | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 30.0A         | NEMA L15-30     |
| SHPAC-6-208-5HP   | 5 HP   | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 30.0A         | NEMA L21-30     |
| SHPAC-6-208-7.5HP | 7.5 HP | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 30.0A         | NEMA L15-30     |
| SHPAC-6-208-7.5HP | 7.5 HP | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 30.0A         | NEMA L21-30     |
| SHPAC-6-208-10HP  | 10 HP  | 200VAC - 240VAC | 3P 4-wire (L1, L2, L3, G) | 41.7A         | 50A Twistlock   |
| SHPAC-6-480-3HP   | 3 HP   | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 9.9A          | NEMA L16-20     |
| SHPAC-6-480-3HP   | 3 HP   | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 9.9A          | NEMA L22-20     |
| SHPAC-6-480-5HP   | 5 HP   | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 14.5A         | NEMA L16-20     |
| SHPAC-6-480-5HP   | 5 HP   | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 14.5A         | NEMA L22-20     |
| SHPAC-6-480-7.5HP | 7.5 HP | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 18.2A         | NEMA L16-20     |
| SHPAC-6-480-7.5HP | 7.5 HP | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 18.2A         | NEMA L22-20     |
| SHPAC-6-480-10HP  | 10 HP  | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 25.1A         | NEMA L16-30     |
| SHPAC-6-480-10HP  | 10 HP  | 380VAC - 480VAC | 3P 4-wire (L1, L2, L3, G) | 25.1A         | NEMA L22-30     |

### Output Power Specifications

| Stagehand Pro Model | HP     | Motor Output Voltage | Motor Output Current | Brake Output Voltage | Combined Brake Output Current |
| :-----------------: | ------ | :------------------: | :------------------: | :------------------: | :---------------------------: |
|   SHPAC-6-208-3HP   | 3 HP   |    200VAC - 240VAC   |         11.0A        |    200VAC - 240VAC   |               6A              |
|   SHPAC-6-208-5HP   | 5 HP   |    200VAC - 240VAC   |         17.5A        |    200VAC - 240VAC   |               6A              |
|  SHPAC-6-208-7.5HP  | 7.5 HP |    200VAC - 240VAC   |         24.0A        |    200VAC - 240VAC   |               6A              |
|   SHPAC-6-208-10HP  | 10 HP  |    200VAC - 240VAC   |         33.0A        |    200VAC - 240VAC   |               6A              |
|   SHPAC-6-480-3HP   | 3 HP   |    380VAC - 480VAC   |         6.0A         |    380VAC - 480VAC   |               6A              |
|   SHPAC-6-480-5HP   | 5 HP   |    380VAC - 480VAC   |         9.5A         |    380VAC - 480VAC   |               6A              |
|  SHPAC-6-480-7.5HP  | 7.5 HP |    380VAC - 480VAC   |         12.0A        |    380VAC - 480VAC   |               6A              |
|   SHPAC-6-480-10HP  | 10 HP  |    380VAC - 480VAC   |         17.0A        |    380VAC - 480VAC   |               6A              |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.creativeconners.com/docs/stagehand/stagehand-pro-6/stagehand-pro-6-specs.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.