Stagehand Lineset: Power Input
Stagehand Lineset ships standard with the following connectors and electrical specifications.
SHLAC-2-208V-3HP-M1/2
3 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
15.7A
NEMA L15-20
SHLAC-2-208V-3HP-M3
3 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
15.7A
NEMA L15-20
SHLAC-2-208V-7.5HP-M1/2
7.5 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
31.2A
NEMA L15-30
SHLAC-2-208V-7.5HP-M3
7.5 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
31.2A
NEMA L15-30
SHLAC-2-208V-10HP-M1/2
10 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
41.7A
50A Twistlock
SHLAC-2-208V-10HP-M3
10 HP
200VAC - 240VAC
3P 4-wire (L1, L2, L3, G)
41.7A
50A Twistlock
SHLAC-2-480-3HP-M1/2
3 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
9.9A
NEMA L16-20
SHLAC-2-480-3HP-M3
3 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
9.9A
NEMA L16-20
SHLAC-2-480-7.5HP-M1/2
7.5 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
18.2A
NEMA L16-20
SHLAC-2-480-7.5HP-M3
7.5 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
18.2A
NEMA L16-20
SHLAC-2-480-10HP-M1/2
10 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
25.1A
NEMA L16-30
SHLAC-2-480-10HP-M3
10 HP
380VAC - 480VAC
3P 4-wire (L1, L2, L3, G)
25.1A
NEMA L16-30
The Stagehand Lineset is equipped with 3 circuit breakers on the front panel.
Flip the MAIN POWER breaker OFF before making or breaking the power connection.
Last updated